Ultrasonic Open Channel Flow Meter
Ultrasonic Open Channel Flow Meter Specification
- Application
- Open Channel Flow Measurement in Sewage, Water, and Industrial Drainage Channels
- Interface Type
- RS485/Modbus
- Measuring Range
- 0.01 m3/h to 99999 m3/h
- Response Time
- 1 Second
- Frequency
- 40 kHz
- Port Size
- DN50 to DN2000
- Accuracy
- 1% FS
- Temperature
- -20C to +60C
- Resolution
- 0.001 m3/h
- Power Supply
- 220V AC, 50Hz
- Features
- Non-contact Measurement, Data Logging, Programmable Outputs, Alarm Function
- Automation Grade
- Automatic
- Operating Voltage
- AC 220V/50Hz or DC 24V (optional)
- Humidity
- 85% RH
- Max Height
- Sensor Installation Height: 1.5 m (max)
- Display Type
- LCD Display
- Equipment Type
- Ultrasonic Open Channel Flow Meter
- Mounting Type
- Wall Mounted
- Usage
- Industrial and Environmental Monitoring
- Machine Weight
- 4.5 kg
- Control Mode
- Microprocessor Based
- Power Consumption
- <2W
- Data Storage
- Internal Memory up to 500,000 Records
- Flow Calculation
- Manning Formula/ISO Standard
- Output Signal
- 4-20 mA, Pulse, RS485
- Enclosure Rating
- IP65
- Relay Output
- 2 Channel Relay Output
- Transmitter Dimensions
- 230 mm 185 mm 120 mm
- Display Language
- English/Chinese
- Calibration
- On-site Calibration Facility
- Installation Method
- Channel Side or Above Channel
- Sensor Dimensions
- 60 mm 32 mm
- Transducer Cable Length
- Standard 10 m, Max 100 m
- Sensor Material
- ABS/SS304
Ultrasonic Open Channel Flow Meter Trade Information
- Minimum Order Quantity
- 1 Unit
- Payment Terms
- Cash in Advance (CID)
- Supply Ability
- 10 Units Per Month
- Delivery Time
- 7 Days
- Main Domestic Market
- All India
About Ultrasonic Open Channel Flow Meter
Targeted Applications & End Users
The Ultrasonic Open Channel Flow Meter is specifically engineered for precise flow monitoring in open channels like sewage, water, and industrial drainage systems. Its rugged design suits both surface-side and above-channel application surfaces. Widely used by plant operators, municipal engineers, and industry professionals, it ensures reliable, accurate results in daily operations. Its flexibility in installation and broad measuring range make it a trusted tool for utilities, environmental agencies, and process industries across varied environments.
Sample Availability & Logistics
Experience our product firsthand with sample units available for evaluation prior to large-scale purchase. With robust supply ability, bulk orders are swiftly shipped from India's leading ports such as Mumbai and Chennai. Each flow meter is carefully packaged and handed over for delivery on order completion, ensuring prompt arrival and condition. We prioritize timely shipping and streamlined logistics so your Ultrasonic Open Channel Flow Meter is ready for seamless commissioning at your site.
FAQ's of Ultrasonic Open Channel Flow Meter:
Q: How does the Ultrasonic Open Channel Flow Meter achieve non-contact flow measurement?
A: The meter employs ultrasonic technology, sending and receiving sound waves above the liquid surface to calculate flow rates accurately without touching the medium, ensuring low maintenance and high reliability.Q: What is the maximum cable length available for the sensor, and how does it affect installation?
A: The sensor comes with a standard 10-meter cable, extendable up to 100 meters, allowing flexibility in installation even in challenging channel environments or remote measurement points.Q: Where can I use this flow meter, and what channel sizes does it support?
A: This instrument is ideal for open channel flow measurement in sewage, water, and industrial drainage systems. It accommodates pipe sizes from DN50 to DN2000, fitting a variety of municipal and industrial setups.Q: What benefits does on-site calibration offer?
A: On-site calibration allows users to precisely adjust and verify flow readings under actual field conditions, ensuring dependable accuracy for every unique installation.Q: When is data logging especially useful, and how is data stored?
A: Data logging is essential for process tracking, compliance, and troubleshooting. The device's internal memory securely stores up to 500,000 flow records for thorough analysis and reporting over extended periods.Q: How is the flow calculation performed by this device?
A: The meter adheres to both Manning formula and ISO standards for open channel flow calculation, ensuring international compliance and trustworthy accuracy in results.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Water Analyzer Category
Electromagnetic Water Flow Meter
Price 25000 INR / Unit
Minimum Order Quantity : 1 Unit
Display Type : Digital LCD/LED
Power Supply : 230V AC 10%, 50Hz
Application : Water flow measurement in industrial, commercial, and municipal sectors
Usage : Online measurement of water flow
Water Level Recorder
Minimum Order Quantity : 1 Unit
Display Type : Digital LCD Display
Power Supply : 9V DC (Battery Operated/External Adapter)
Application : Groundwater, hydrological & industrial water level measurement
Usage : Water level monitoring in wells, reservoirs, tanks etc.
DO Analyzer
Price 120000 INR / Unit
Minimum Order Quantity : 1 Unit
Display Type : Keypad
Power Supply : 220 V
Usage : Laboratory Analysis
Digital PH Analyzer
Price 56000 INR / Unit
Minimum Order Quantity : 1 Unit
Display Type : Digital
Application : Laboratory
Usage : PH measurement
![]() |
ENVIRO EMPIRICAL (INDIA) PRIVATE LIMITED